Basic Info
1. 16A contact switching capability
2.Normally open type has the UL certification of TV-8 125VAC, the impact current is 120A
3.The withstand voltage between coil and contact can reach 10KV
4. Optional socket installation
Contact Data:
General Data:
Coil Data:
Standard:
Sensitive:
- Model NO.: W39
- Contact Form: 1A= 1OPEN 1C = 1 Transformation
- PCB Mounting: 1 = type 1 2= type 2
- Product protective: S=Sealed Nil= Soldered
- Contact material: T = AgSnO2
- Coil Power: Nil = 530mW L= 360mW
- Insulation level: B: B level F: F level
- Dimension: 29*12.7*25 MM
- Weight: Approx 15g
- Trademark: FANHAR
- Origin: China
1. 16A contact switching capability
2.Normally open type has the UL certification of TV-8 125VAC, the impact current is 120A
3.The withstand voltage between coil and contact can reach 10KV
4. Optional socket installation
Contact Data:
Contact Form | 1A 1C |
Rated load | 16A 250VAC/30VDC 12A 250VAC/30VDC |
Max Switching Voltage | 277VAC/ 30VDC |
Max Switching Current | 16A |
Max Switching Capacity | 4000VA/480W |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 100mΩ (at 6VDC 1A) |
Insulation Resistance | 1000MΩ (at 500VDC) |
General Data:
Withstand Voltage Between open contacts | 1000VAC 1min |
Between coil and contacts | 4000VAC 1min |
Operate Time | Max.15ms |
Release Time | Max.5ms |
Mechanical life | 10,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 16A 250VAC /30VDC 100,000 ops ON/OFF=1s/9s 12A 250VAC /30VDC 100,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation Durability | 100m/s² Approx10G 1000m/s² Approx100G |
Vibration Resistance Misoperation Durability | 10 - 55 Hz 1.5mm Double Amplitude 10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40ºC to +70ºC |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Certification | UL TUV ISO CQC |
Coil Data:
Standard:
Coil rated voltage | Operating voltage | Releasing Voltage | Coil rated Current (±10%) | Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) | above 5% rated voltage (initial) | 106mA | 47Ω | 530mW | 90-130 % Rated voltage |
DC 6V | 58.8mA | 153Ω | ||||
DC 12V | 44.2mA | 272Ω | ||||
DC 24V | 22.1mA | 1087Ω | ||||
DC 48V | 11.5mA | 4170Ω | ||||
DC 100V | 5.3mA | 18860Ω |
Sensitive:
Coil rated voltage | Operating voltage | Releasing Voltage | Coil rated Current (±10%) | Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) | above 5% rated voltage (initial) | 71.4mA | 70Ω | 360mW | 90-130 % Rated voltage |
DC 6V | 60mA | 100Ω | ||||
DC 12V | 30mA | 400Ω | ||||
DC 24V | 15mA | 1600Ω | ||||
DC 48V | 7.5mA | 6400Ω |